WiSER 3X Quick Guide

Welcome to the Wiser3x experience, a 3-axis Wireless Accelerometer specially designed for vibration analysis, compatible with any vibration analyzer available on the market. WiSER 3x sends vibration data from 3 axes + 1 additional channel simultaneously. In addition, WiSER 3x is an ultra-low noise wireless accelerometer with a 15 kHz bandwidth that exceeds the characteristics of most conventional accelerometers.
The power button on our WiSer3x is designed to prevent it from being accidentally turned off or on. Press the button once to turn on and 3 seconds to turn off.
Once turned on, our WiSer3x can be detected through the WiFi network of any Apple, Android or Windows device. You can connect to it like any other WiFi signal and its password is: 88888888.
Next we will tell you how to synchronize it with Erbessd Instruments applications.

Digivibe MX 10

Off-route Analysis in DigivibeMX v10 Software:

Open the Analyze menu, select the WiSer3x button. You should receive a “WiSer 3x is paired up” notification. Click Ok. When ready, click record to begin recording.
NOTE: If you do not receive the “WiSer 3x is paired up” notification, ensure the WISer3x has not timed out and turned off. Also ensure that the computer has not disconnected from the WISer3x as its WiFi source.

Route data collection in DigivibeMX v10 Software: Open a New Route. On the Routes menu, select and highlight the WiSer3x Icon. You should receive a “WiSer 3x is paired up” notification. Click Ok. Select A3 to simultaneously 3-axis collect data. Click Axis Configuration to specify the sensor orientation and axis configuration, then click Ok. When ready, click record to begin a triaxial data collection of the first point.

NOTE: The position of the WiSer3x on the machine is very important for the correct measurement of vibration data. For the vertical configuration, make sure that the engraving of the axes is facing you, and for the horizontal case, the engraving should face upwards.

DigivibeMX 11

For off-route data collection in DigivibeMX 11 Software: Configure DigivibeMX v11 software to receive data from the WiSER3x interface. On the Configuration Menu, toggle the USB Connection button to WiFi Connection.

Once the configuration has been changed to WiFi we click on the “Analyze tab and select the “Connect WiFi” button and when this button disappears our Wiser3x will be completely linked to our computer and the software. You can start a new analysis normally and press the record button to start collecting data.

Route Data Collection in DigivibeMX v11 Software: On the Start menu, select Start Route. Or click the Route tile on the Start screen. Once in the menu select and click on the icon showing 3 Axis. Next, click on the configuration icon to display the Wiser3x position options on the machine. Once the position is selected, click “Ok” and the software is ready to start collecting data.

NOTE: The position of the WiSer3x on the machine is very important for the correct measurement of vibration data. For the vertical configuration, make sure that the engraving of the axes is facing you, and for the horizontal case, the engraving should face upwards.

For Wiser-Vibe

Off-route data collection using the WiSER VIBRE PRO app on iOS & Android:
a. Open and select the Analysis box.
b. Choose the “Off Route” menu.
c. Open the Connection Manager.

d. Choose the “Connect to Wiser” option.
e. Setup your recording preferences and click in the “Back” button.
f. Press record and your measurement will be taken.

Select “Save File” from the options (upper right corner) to save the recording to your iOS or Android device as an .anl file. All files can be viewed by returning to the main screen and selecting the “Files” option. Saved files can be mailed directly from WiSerVibe. Mailed files can be opened with DigivibeMX for analysis.

Saved files can be mailed directly from WiSerVibe. Using the options menu (uper right corner) with the “Share” button. Then you will need to select the files you want to share and click on the icon on the right. Then you can select your preferred app to send the file. Mailed files can be opened with DigivibeMX for analysis.

On-route data collection using an EI-Analytics account and the WiSER VIBE PRO iOS & Android app:
1. Connect your EI-Analytic account on the main screen. Type your credentials, select your database and click Save.

2. The key is displayed green when connecting. Access to the lower right tile to access to the “Groups” window. And select the folder where the route you want record is stored.

3. Confirm your selection on the “General Info” page and then click “Go”. Connect to the WiSER using the “Connection Manager” and then set your WiSER as desired.

3. Take your measurements using the record button and when the route is finished. Choose if you want to place the ruta on a queue or upload it manually later. To check your files access to the main menu and press the lower left tile.

4. Select the options menu located on the upper right corner. Choose “Upload to the cloud” and then locate the folder corresponding to your route and click the “Upload” button.

NOTE: The use and connectivity with the EI-Analytic Cloud database will only be functional in the case of having previously contracted the service. The cloud database service is not included in the download of the application, nor in the purchase of the measurement devices.