Multiparameter Sensor | Vibration, Current, and Temperature

- Overview
- Features
- Specs
- Documents
Phantom All in One (EPH-U14) | Vibration, Current, and Temperature
Meet the new member of the Phantom family. Take 3 types of measurement parameters with only one module: vibration, current, and temperature. Our Phantom condition monitoring system will help you to predict machine failures and save huge amount of costs due to non-programmed down times in production.
Vibration
The vibration Phantom is the best all-inclusive battery powered wireless machine monitoring system worldwide. Phantom records vibration FFTs from 3 axes simultaneously X, Y and Z.
- Triaxial
- Full waveform and spectrum data
- Programmable internal RMS trigger
- Maximum 6,400 lines of resolution
Current
The current Phantom is a wireless current sensor (amperage) which uses a simple current transformer for monitoring. Easily monitor the AC electrical current of your machines and devices.
- 1 split core current transformer.
- Available clamps from 50 to 500 Amp (not included).
Temperature
The temperature Phantom is a Bluetooth temperature sensor designed to monitor a machine’s temperatures. Easily connect any type K thermocouple sensor (not included). This wireless thermocouple sensor can record accurately from -210ºC up to 1,800ºC.
- Compatible with type K sensors (not included).
- Easy to install.
- It can sensor from -210°C to 1800°C.
Main Features
- Full waveform and spectrum data
- Configurable alarm interval
- Battery life enough to take up to 100,000 measurements
- Configurable measurement interval
- Measures 4 Channels simultaneously.
- Compatible with type K sensors.
- Measures 4 Channels simultaneously.
- Compatible with 50A, 100A, 250A and 500A clamps
- IP67 design for protection from liquid and dust
MEASUREMENT
Vibration | |||||
Part number | Vibration sensor | ||||
Sensor | MEMS tri-axis accelerometer | ||||
Frequency Range (@25600 SR) | 10kHz (x,y); 5.1kHz (z) | ||||
Dynamic Range | 8 G / 16 G / 32 G | ||||
Internal Temp. Accuracy | ±5°C | ||||
Status (Every 5min) | Internal RMS, battery, temperature, alarm | ||||
Recording Time (s) | 1 | 2 | 4 | 8 | 16 |
Sample Rate (Hz) | 25,600 | 12,800 | 6,400 | 3,200 | 1,600 |
Max Frequency (Hz) | 10,000 | 5,000 | 2,500 | 1,250 | 625 |
Lines of Resolution | 6,400 | ||||
Data Interval | 10 minutes configurable or specific daytime | ||||
Alarm monitoring | 2 – 120 sec. | ||||
Spectral Noise | 630 µg/√Hz | ||||
Current | |||||
Part Number | Current module | ||||
Sensor | Split core current transformer sensor | ||||
CT sensor compatibility | 50 Amp / 100 Amp / 250 Amp / 500 Amp | ||||
Frequency Range | 50 – 60 Hz | ||||
Accuracy | ±5% | ||||
Internal Temp. Accuracy | ±5°C | ||||
Measurement (RMS AC Current) | Minimum / Maximum / Average / Amp Hour | ||||
Data Interval | 30 min / configurable | ||||
Notes | Only for monitoring AC current | ||||
Temperature | |||||
Part Number | Temperature sensor | ||||
Sensor Compatibility | Thermocouple type K | ||||
Temperature Range | Ambient | – 40 to +80 °C | |||
Object | – 210 to +1800 °C (Depends on Thermocouple) | ||||
Internal Temp. Accuracy | ±5°C | ||||
Status (Every 5min) | Battery, temperature sensor, temperature object | ||||
Data Interval | 30 min / configurable | ||||
Accessories Included | Thermocouple type K |
CONNECTIVITY AND SOFTWARE
Wireless Protocol | Bluetooth BLE 5.0 / Modbus via Gateway | ||||
Operating Frequency | 2.4 GHz | ||||
Power Output Range | -4dBm to +8dBm (configurable) | ||||
Signal Strength Range | -90dBm to -30 dBm | ||||
Wireless Range | 100m line of sight | ||||
Software Compatibility | DigivibeMX Phantom version, WiSER VIBE | ||||
OTA firmware update via Phantom Manager app (iOS / Android) |
POWER SUPPLY
Main Power | 2 x Battery AAA 1.5V (Replaceable) | ||||
Battery Life Time | 2-3 years* | ||||
*Standby mode if gateway not detected |
DIMENSIONS AND FIXTURE
Dimensions (w x l x h) | 100mm x 77mm x 26mm | ||||
Weight | 138gr | ||||
Enclosure Material | Nylamid / Aluminum | ||||
Protection Rating | Water and dust resistant IP67 |
ENVIROMENTAL CONDITIONS
Base Temperature Range | -40 to +85 °C (-40 to +185 °F) |