{"id":10078818,"date":"2020-07-01T14:24:33","date_gmt":"2020-07-01T19:24:33","guid":{"rendered":"https:\/\/www.erbessd-instruments.com\/docs\/phase-analysis"},"modified":"2021-07-26T14:27:51","modified_gmt":"2021-07-26T19:27:51","slug":"analisisdefase","status":"publish","type":"docs","link":"https:\/\/www.erbessd-instruments.com\/es\/docs\/digivibemx\/digivibe-10\/analisisdefase\/","title":{"rendered":"An\u00e1lisis de Fase"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"10078818\" class=\"elementor elementor-10078818 elementor-10078713\" data-elementor-post-type=\"docs\">\n\t\t\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-101233d7 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"101233d7\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-287e9d65\" data-id=\"287e9d65\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2484e2d3 elementor-widget elementor-widget-text-editor\" data-id=\"2484e2d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El objetivo del an\u00e1lisis es encontrar la fase entre la vibraci\u00f3n horizontal y vertical, o en cualquier otra direcci\u00f3n.<br \/><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-10095776 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-1.jpg\" alt=\"\" width=\"592\" height=\"389\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-1.jpg 592w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-1-300x197.jpg 300w\" sizes=\"(max-width: 592px) 100vw, 592px\" \/><br \/>Con el DigivibeMX se tienen 3 maneras de determinar fases :<\/p><ul><li>Funci\u00f3n Phase shift (m\u00e9todo gr\u00e1fico)<\/li><li>Fase por Frecuencias (m\u00e9todo num\u00e9rico)<\/li><li>Fase usando los datos de una ruta de ODS<\/li><\/ul><h1>Funci\u00f3n Phase Shift<\/h1><p>Inicie un nuevo an\u00e1lisis y grabe 3s (o m\u00e1s) con 2 canales :<br \/><img decoding=\"async\" class=\"aligncenter wp-image-10095780 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-2.jpg\" alt=\"\" width=\"1238\" height=\"325\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-2.jpg 1238w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-2-300x79.jpg 300w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-2-1024x269.jpg 1024w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-2-768x202.jpg 768w\" sizes=\"(max-width: 1238px) 100vw, 1238px\" \/><br \/>Haga clic en \u00ab Functions \u00bb y seleccione \u00ab Phase \u00bb :<br \/><img decoding=\"async\" class=\"aligncenter wp-image-10095784 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-3.jpg\" alt=\"\" width=\"1257\" height=\"459\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-3.jpg 1257w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-3-300x110.jpg 300w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-3-1024x374.jpg 1024w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-3-768x280.jpg 768w\" sizes=\"(max-width: 1257px) 100vw, 1257px\" \/><br \/>Seleccione el Canal 1 como Referencia para ser la fase 0\u00b0 (o tambi\u00e9n puede ser el Canal 2) y haga clic en Ok:<br \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10095788 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-4.jpg\" alt=\"\" width=\"361\" height=\"318\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-4.jpg 361w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-4-300x264.jpg 300w\" sizes=\"(max-width: 361px) 100vw, 361px\" \/><br \/>Se obtiene este gr\u00e1fico. Agrande la zona que corresponde a la frecuencia de 1754 CPM (la velocidad de rotaci\u00f3n):<br \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10095792 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-5.jpg\" alt=\"\" width=\"1186\" height=\"575\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-5.jpg 1186w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-5-300x145.jpg 300w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-5-1024x496.jpg 1024w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-5-768x372.jpg 768w\" sizes=\"(max-width: 1186px) 100vw, 1186px\" \/><br \/>La fase en esta frecuencia es de 226\u00b0. Se puede colocar un marcador y copiar el gr\u00e1fico para integrarlo al reporte:<br \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10095796 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-6.jpg\" alt=\"\" width=\"1251\" height=\"610\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-6.jpg 1251w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-6-300x146.jpg 300w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-6-1024x499.jpg 1024w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-6-768x374.jpg 768w\" sizes=\"(max-width: 1251px) 100vw, 1251px\" \/><\/p><h1>Fase por Frecuencias<\/h1><p>Para conocer la fase entre 2 se\u00f1ales grabadas simultaneamente o bien entre el <strong>Punto 1 \u2013 Horizontal <\/strong>y el <strong>Punto 1 \u2013 Vertical <\/strong>de una ruta con punto de referencia de la m\u00e1quina <strong>Machine 1<\/strong>, seleccione por ejemplo el <strong>Punto 1 \u2013 Horizontal <\/strong>como Canal 1:<br \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10095802 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-7.jpg\" alt=\"\" width=\"1228\" height=\"225\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-7.jpg 1228w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-7-300x55.jpg 300w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-7-1024x188.jpg 1024w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-7-768x141.jpg 768w\" sizes=\"(max-width: 1228px) 100vw, 1228px\" \/><\/p><p>Ahora agregue la 2nda se\u00f1al<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10095806 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-8.jpg\" alt=\"\" width=\"518\" height=\"229\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-8.jpg 518w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-8-300x133.jpg 300w\" sizes=\"(max-width: 518px) 100vw, 518px\" \/><br \/><strong>IMPORTANTE :<\/strong><br \/>Si las 2 se\u00f1ales NO fueron grabadas al mismo tiempo o no provienen de una ruta con punto de referencia (rutas que se realizan con 2 sensores seleccionando el canal 2 como la Referencia F) entonces la medici\u00f3n de Fase <strong>no es v\u00e1lida<\/strong>.<br \/>El <strong>Punto 1 &#8211; Vertical <\/strong>es el Canal 2:<br \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10095810 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-9.jpg\" alt=\"\" width=\"1190\" height=\"214\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-9.jpg 1190w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-9-300x54.jpg 300w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-9-1024x184.jpg 1024w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-9-768x138.jpg 768w\" sizes=\"(max-width: 1190px) 100vw, 1190px\" \/><br \/>Haga clic en Ok :<br \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10095814 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-10.jpg\" alt=\"\" width=\"349\" height=\"411\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-10.jpg 349w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-10-255x300.jpg 255w\" sizes=\"(max-width: 349px) 100vw, 349px\" \/><br \/>Ahora seleccione la pesta\u00f1a <strong>Analyze <\/strong>en la parte superior:<br \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10095818 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-11.jpg\" alt=\"\" width=\"1258\" height=\"688\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-11.jpg 1258w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-11-300x164.jpg 300w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-11-1024x560.jpg 1024w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-11-768x420.jpg 768w\" sizes=\"(max-width: 1258px) 100vw, 1258px\" \/><br \/><strong>Luego la pesta\u00f1a Analyze <\/strong>arriba:<br \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10095903 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-12.jpg\" alt=\"\" width=\"1262\" height=\"670\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-12.jpg 1262w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-12-300x159.jpg 300w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-12-1024x544.jpg 1024w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-12-768x408.jpg 768w\" sizes=\"(max-width: 1262px) 100vw, 1262px\" \/><br \/>Seleccione la velocidad en CPM, el canal de referencia (en esta caso Canal 1) y la tabla mostrar\u00e1 la Fase entre las 2 se\u00f1ales, usando la referencia como Fase 0\u00b0.<br \/>En este ejemplo, la fase entre Canal 1 y Canal 2 es de : <strong>226\u00b0<\/strong><br \/>Puede colocar marcadores en la gr\u00e1fica:<br \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10095908 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-13.jpg\" alt=\"\" width=\"1249\" height=\"681\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-13.jpg 1249w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-13-300x164.jpg 300w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-13-1024x558.jpg 1024w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-13-768x419.jpg 768w\" sizes=\"(max-width: 1249px) 100vw, 1249px\" \/><br \/>Puede colocar otros marcadores correspondientes a otras frecuencias en la misma gr\u00e1fica:<br \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10095912 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-14.jpg\" alt=\"\" width=\"1262\" height=\"688\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-14.jpg 1262w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-14-300x164.jpg 300w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-14-1024x558.jpg 1024w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-14-768x419.jpg 768w\" sizes=\"(max-width: 1262px) 100vw, 1262px\" \/><br \/>Ahora puede copiar el gr\u00e1fico (bot\u00f3n derecho sobre la gr\u00e1fica) para incluirlo en su reporte.<\/p><h1>Fase usando los datos de una ruta de ODS<\/h1><p>Seleccione la m\u00e1quina que desea analizar e inicie la funci\u00f3n \u00ab ODS 3D \u00bb :<br \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10095916 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-15.jpg\" alt=\"\" width=\"1215\" height=\"684\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-15.jpg 1215w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-15-300x169.jpg 300w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-15-1024x576.jpg 1024w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-15-768x432.jpg 768w\" sizes=\"(max-width: 1215px) 100vw, 1215px\" \/><br \/>Seleccione la ruta por fecha y las RPM para el an\u00e1lisis de fase :<br \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10095920 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-16.jpg\" alt=\"\" width=\"1257\" height=\"673\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-16.jpg 1257w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-16-300x161.jpg 300w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-16-1024x548.jpg 1024w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-16-768x411.jpg 768w\" sizes=\"(max-width: 1257px) 100vw, 1257px\" \/><br \/>Seleccione \u00ab Points \u00bb y haga click en el punto que desea analizar :<br \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10095924 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-17.jpg\" alt=\"\" width=\"1255\" height=\"670\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-17.jpg 1255w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-17-300x160.jpg 300w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-17-1024x547.jpg 1024w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-17-768x410.jpg 768w\" sizes=\"(max-width: 1255px) 100vw, 1255px\" \/><br \/>Se calculan las fases entre todos los puntos <strong>con respecto <\/strong>a la Referencia :<\/p><ul><li>Horizontal<\/li><li>Vertical<\/li><li>Axial<\/li><\/ul><p>Reste la fase del punto y direcci\u00f3n que le interesa con respecto al 2ndo punto de inter\u00e9s y as\u00ed obtiene la fase entre ellos (por ejemplo la Fase entre 1H y 1V = 358\u00b0 \u2013 238\u00b0 = 120\u00b0).<br \/><strong>IMPORTANTE : <\/strong>Aseg\u00farese de que las mediciones fueron tomadas en las direcciones indicadas en la figura 3D, de lo contrario seleccione la casilla \u00ab Inv \u00bb para invertir la direcci\u00f3n en un punto dado (la flecha de la direcci\u00f3n cambiar\u00e1 de sentido).<br \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-10095928 size-full\" src=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-18.jpg\" alt=\"\" width=\"611\" height=\"587\" srcset=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-18.jpg 611w, https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-18-300x288.jpg 300w\" sizes=\"(max-width: 611px) 100vw, 611px\" \/><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"featured_media":0,"parent":10078712,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","doc_tag":[],"class_list":["post-10078818","docs","type-docs","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v22.8 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Docs for Digivibe 10 &#8211; An\u00e1lisis de Fase &#8211; ERBESSD INSTRUMENTS<\/title>\n<meta name=\"description\" content=\"ERBESSD INSTRUMENTS Tutorials for Digivibe 10 An\u00e1lisis de Fase\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.erbessd-instruments.com\/es\/docs\/digivibemx\/digivibe-10\/analisisdefase\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"An\u00e1lisis de Fase\" \/>\n<meta property=\"og:description\" content=\"ERBESSD INSTRUMENTS Tutorials for Digivibe 10 An\u00e1lisis de Fase\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.erbessd-instruments.com\/es\/docs\/digivibemx\/digivibe-10\/analisisdefase\/\" \/>\n<meta property=\"og:site_name\" content=\"ERBESSD INSTRUMENTS\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/erbessdinstrumentsco\" \/>\n<meta property=\"article:modified_time\" content=\"2021-07-26T19:27:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-1.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@ErbessdRel\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutos\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Docs for Digivibe 10 &#8211; An\u00e1lisis de Fase &#8211; ERBESSD INSTRUMENTS","description":"ERBESSD INSTRUMENTS Tutorials for Digivibe 10 An\u00e1lisis de Fase","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.erbessd-instruments.com\/es\/docs\/digivibemx\/digivibe-10\/analisisdefase\/","og_locale":"es_ES","og_type":"article","og_title":"An\u00e1lisis de Fase","og_description":"ERBESSD INSTRUMENTS Tutorials for Digivibe 10 An\u00e1lisis de Fase","og_url":"https:\/\/www.erbessd-instruments.com\/es\/docs\/digivibemx\/digivibe-10\/analisisdefase\/","og_site_name":"ERBESSD INSTRUMENTS","article_publisher":"https:\/\/www.facebook.com\/erbessdinstrumentsco","article_modified_time":"2021-07-26T19:27:51+00:00","og_image":[{"url":"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-1.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_site":"@ErbessdRel","twitter_misc":{"Tiempo de lectura":"6 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.erbessd-instruments.com\/es\/docs\/digivibemx\/digivibe-10\/analisisdefase\/","url":"https:\/\/www.erbessd-instruments.com\/es\/docs\/digivibemx\/digivibe-10\/analisisdefase\/","name":"Docs for Digivibe 10 &#8211; An\u00e1lisis de Fase &#8211; ERBESSD INSTRUMENTS","isPartOf":{"@id":"https:\/\/www.erbessd-instruments.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.erbessd-instruments.com\/es\/docs\/digivibemx\/digivibe-10\/analisisdefase\/#primaryimage"},"image":{"@id":"https:\/\/www.erbessd-instruments.com\/es\/docs\/digivibemx\/digivibe-10\/analisisdefase\/#primaryimage"},"thumbnailUrl":"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-1.jpg","datePublished":"2020-07-01T19:24:33+00:00","dateModified":"2021-07-26T19:27:51+00:00","description":"ERBESSD INSTRUMENTS Tutorials for Digivibe 10 An\u00e1lisis de Fase","breadcrumb":{"@id":"https:\/\/www.erbessd-instruments.com\/es\/docs\/digivibemx\/digivibe-10\/analisisdefase\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.erbessd-instruments.com\/es\/docs\/digivibemx\/digivibe-10\/analisisdefase\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.erbessd-instruments.com\/es\/docs\/digivibemx\/digivibe-10\/analisisdefase\/#primaryimage","url":"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-1.jpg","contentUrl":"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2020\/07\/Phase-Analysis-1.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.erbessd-instruments.com\/es\/docs\/digivibemx\/digivibe-10\/analisisdefase\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.erbessd-instruments.com\/es\/"},{"@type":"ListItem","position":2,"name":"DigivibeMX","item":"https:\/\/www.erbessd-instruments.com\/it\/docs\/digivibemx\/"},{"@type":"ListItem","position":3,"name":"Digivibe 10","item":"https:\/\/www.erbessd-instruments.com\/it\/docs\/digivibemx\/digivibe-10\/"},{"@type":"ListItem","position":4,"name":"An\u00e1lisis de Fase"}]},{"@type":"WebSite","@id":"https:\/\/www.erbessd-instruments.com\/#website","url":"https:\/\/www.erbessd-instruments.com\/","name":"ERBESSD INSTRUMENTS","description":"Vibration Analyzer, Online Monitoring, Video Deflection, &amp; Balancing Machine Manufacturer","publisher":{"@id":"https:\/\/www.erbessd-instruments.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.erbessd-instruments.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.erbessd-instruments.com\/#organization","name":"ERBESSD INSTRUMENTS","url":"https:\/\/www.erbessd-instruments.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.erbessd-instruments.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2021\/06\/erbessd_instruments_logo.png","contentUrl":"https:\/\/www.erbessd-instruments.com\/wp-content\/uploads\/2021\/06\/erbessd_instruments_logo.png","width":1073,"height":138,"caption":"ERBESSD INSTRUMENTS"},"image":{"@id":"https:\/\/www.erbessd-instruments.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/erbessdinstrumentsco","https:\/\/x.com\/ErbessdRel","https:\/\/www.linkedin.com\/company\/erbessdinstrumentsco","https:\/\/www.pinterest.com\/4d2ab37d590061eda78ee907c11410\/","https:\/\/www.youtube.com\/channel\/UCMi2XxcHeufIw5WVkcPg98A"]}]}},"comment_count":0,"_links":{"self":[{"href":"https:\/\/www.erbessd-instruments.com\/es\/wp-json\/wp\/v2\/docs\/10078818","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.erbessd-instruments.com\/es\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/www.erbessd-instruments.com\/es\/wp-json\/wp\/v2\/types\/docs"}],"replies":[{"embeddable":true,"href":"https:\/\/www.erbessd-instruments.com\/es\/wp-json\/wp\/v2\/comments?post=10078818"}],"version-history":[{"count":6,"href":"https:\/\/www.erbessd-instruments.com\/es\/wp-json\/wp\/v2\/docs\/10078818\/revisions"}],"predecessor-version":[{"id":10098541,"href":"https:\/\/www.erbessd-instruments.com\/es\/wp-json\/wp\/v2\/docs\/10078818\/revisions\/10098541"}],"up":[{"embeddable":true,"href":"https:\/\/www.erbessd-instruments.com\/es\/wp-json\/wp\/v2\/docs\/10078712"}],"next":[{"title":"Bump Test","link":"https:\/\/www.erbessd-instruments.com\/docs\/digivibemx\/digivibe-10\/bump-test\/","href":"https:\/\/www.erbessd-instruments.com\/es\/wp-json\/wp\/v2\/docs\/10078823"}],"wp:attachment":[{"href":"https:\/\/www.erbessd-instruments.com\/es\/wp-json\/wp\/v2\/media?parent=10078818"}],"wp:term":[{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/www.erbessd-instruments.com\/es\/wp-json\/wp\/v2\/doc_tag?post=10078818"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}